鑫源大厦建筑给水排水工程设计.rar

资料分类:工程技术 上传会员:笑笑 更新时间:2014-07-19
需要金币1000 个金币 资料包括:完整论文 下载论文
转换比率:金额 X 10=金币数量, 例100元=1000金币 论文字数:25887
折扣与优惠:团购最低可5折优惠 - 了解详情 论文格式:Word格式(*.doc)

摘要:本设计是关于铜山区鑫源大厦的建筑给水排水设计,主要是建筑给水、排水、热水、消防系统的设计。

   本设计的建筑位于徐州市铜山区,是一栋12层高的综合性民用建筑。给排水工程设计包括了室内生活给水系统设计、室内排水系统设计、室内消防给水系统设计、以及雨水系统设计。生活给水系统分为两个区,一至二层为低区,采用市政给水管网直接供水,三层至十二层为高区,利用屋顶高位水箱给系统供水。消防给水系统分为消火栓给水系统和自动喷淋灭火系统,本建筑为一类民用建筑,而其建筑高度≥50m,按《高层民用建筑防火设计规范》规定,室内消火栓用水量和室外消火栓用水量分别取20L/s和15L/s自动喷淋系统计算用水量为16L/s,自动喷淋系统在屋顶设增压设备。排水系统采用污废合流制,排水系统采用特殊的伸顶通气单立管排水系统,通气冒高出屋顶1.00m。给水系统采用PP-R给水管材,消火栓给水系统和自动喷淋灭火系统采用无缝镀锌钢管,排水系统立管采用PPI螺旋排水管,各层排水支管采用普通的UPVC排水管。在地下层设贮水池和加压泵房,地下室另设集水坑,集水坑中设潜污泵,保证污水及时排出。

关键词 建筑给水;建筑排水;消防;喷淋;热水

 

Abstract:The design of building water supply and drainage of Copper Mt. Xinyuan building design, design is the main building water supply, drainage, water, fire control system.

   The design of the building is located in Xuzhou District of Copper Mt. City, is a comprehensive civil building 12 tall. Including indoor living water supply system design, indoor drainage system design, indoor fire water supply system design, and the design of rainwater system design of water supply and drainage engineering. Life water supply system is divided into two zones, one to two layers as low area, the municipal water supply pipe network to supply water directly, the three layer to the twelve layer for high, use of roof water tank for water supply system. Fire water supply system is divided into fire hydrant system and automatic sprinkler system, the construction of a class of civil building, and the building height greater than 50m, according to the "Regulations" code for design of fire system of high rise civil buildings, indoor fire hydrant water and outdoor fire hydrant water respectively from the 20L/s and 15L/s of the automatic sprinkler system, calculation of water for 16L/s, automatic sprinkler system with pressurized equipment on the roof. Drainage system using sewage waste sewage system, drainage system with special ventilating single stack drainage system, ventilation at high roof 1.00m. Water supply system adopts PP-R water supply pipe, fire hydrant system and automatic sprinkler system adopts the seamless galvanized steel pipe, drainage riser with PPI spiral drainage pipe, the drainage pipes using ordinary UPVC drainage pipe. In the underground layer is provided with a storage tank and the pressure pump, the basement a sump, sump is arranged in the submersible sewage pump sewage discharged timely, ensure.  

Keywords:Building water supply.drainage. construction fire water spray

相关论文资料:
最新评论
上传会员 笑笑 对本文的描述:通过毕业设计,使学生熟悉掌握给排水工程设计程序、方法和技术规范,提高对给排水工程设计的计算、图表绘制、计算说明书的编写;树立正确的设计思想,培养学生严肃认真的科学......
发表评论 (我们特别支持正能量传递,您的参与就是我们最好的动力)
注册会员后发表精彩评论奖励积分,积分可以换金币,用于下载需要金币的原创资料。
您的昵称: 验证码: