需要金币:1000 个金币 | 资料包括:完整论文 | ||
转换比率:金额 X 10=金币数量, 例100元=1000金币 | 论文字数:8793 | ||
折扣与优惠:团购最低可5折优惠 - 了解详情 | 论文格式:Word格式(*.doc) |
摘要:采用电导率法快速检测样本中大肠杆菌数量来判断茶饮料中大肠杆菌是否超标。先建立了利用电导率法测定几种常见食品细菌总数的标准曲线,然后通过平行实验验证了电导率法快速检测食品细菌总数的重现性,再通过配对实验比较了电导率法与国标法测定结果符合率;结果统计出0.1>p>0.05,说明两种方法无显著差异;说明电脑率法是可以用来快速检测细菌总数的。 关键词 大肠杆菌;电导率法;国标法
Abstract:Number of e. coli in rapid detection of samples by conductivity method to judge the excessive e. coli in the tea beverage. First established using the method of electric conductivity determination of several kinds of common food bacteria of the total number of standard curve, and then by parallel experiments to verify the reproducibility of the total electrical conductivity method for rapid detection of food bacteria, again through the matching experiment compared the electrical conductivity method and gb method determination results coincidence rate; 0.1> p >0.05 result the statistics shows that two methods had no significant difference; That computer rate method can be used for rapid detection of the total number of bacteria Keywords E. Coli Conductivity method National standard method |